Three recurring problems our customers faced before Eziwan—and how Modbus RS-485 monitoring solved them.
From the electrical cabinet to the cloud dashboard in 3 steps. No integrator required.
Predefined Modbus templates for the most common meters in France, Belgium, and the Netherlands. Any Modbus RTU RS-485 device can also be configured manually.
The de facto standard for industrial monitoring. Comprehensive measurement: voltages, currents, power, power factor, THD, harmonics, energy.
Compact single-phase 1 DIN meter. Ideal for monitoring individual pieces of equipment or small utility rooms.
Compact version with 4 DIN modules. Three-phase measurement with integrated load profile. Perfect for crowded panels.
Single-phase meter with LCD display. Local reading and Modbus communication. Ideal for secondary measurement points.
Enhanced version with peak demand measurement and an 8-rate load profile. MID-compliant for tax purposes.
Class 0.5S precision meter for delivery points requiring billing accuracy. MID-certified.
Modbus TCP-compatible WAGO data acquisition module. Integrates into existing WAGO control cabinets without additional wiring.
Schneider network analyzer with a built-in 35-day load profile. Internal alarms and programmable logic outputs.
A meter widely used in the European service sector. Compact 4-DIN-module design; measures THD and power factor per phase.
For any Modbus RTU RS-485 device: configure the slave address, registers, and scale factor in the Eziwan web interface.
From multi-register Modbus data collection to Power BI exports and ISO 50001 compliance—the entire energy monitoring cycle in a single solution.
Query up to 200 Modbus registers per gateway, distributed across multiple RS-485 slaves or multiple Modbus TCP addresses. Supports Holding Register, Input Register, Coil, and Discrete Input types. Polling is configurable on a per-register basis: 1 second for active power, 15 minutes for cumulative energy. Compatible with Modbus RTU over RS-232 and RS-485, and Modbus TCP/IP.
Real-time load curves for active power (kW), reactive power (kVAR), power factor cos φ, total harmonic distortion (THD-V and THD-I), and energy consumed/injected (kWh). Zoom range from 1 minute to 2 years. Comparison between periods (week N vs. week N-1). Multi-site view on a single map.
Configure alert rules for any Modbus variable: peak power exceedance, undervoltage (alert before the circuit breaker trips), abnormal nighttime power consumption. Configurable trigger delay to prevent false positives caused by transient spikes. Acknowledgment with operator comments and a time-stamped alert log.
Download your historical data as CSV files for import into Excel or directly into Tableau/Power BI via the OAuth2-authenticated REST API. Data is available in JSON with ISO 8601 UTC timestamps. Configurable webhooks to push data in real time to your data warehouse (AWS S3, Azure Blob, InfluxDB v2, TimescaleDB).
Automatically generate reports tracking energy efficiency indicators (EEI) required by ISO 50001: consumption per UEP (Basic Production Unit), energy baseline, and reduction targets. Export monthly or annual PDF reports featuring your company’s logo. Compliant with the requirements of the Tertiary Sector Decree and the Energy Efficiency Directive (EED) obligations.
All measurements are stored as time series for 24 months. Raw data is available for the last 30 days; beyond that, data is automatically aggregated by the minute (min, max, average, standard deviation) to optimize storage without losing statistical information. Retention periods of up to 5 years are available upon request.
Factories, production sites, multi-machine workshops: the manufacturing industry is the primary sector for Modbus energy monitoring.
Answers to questions from energy managers, system integrators, and facility managers regarding the connection of Eastron, Schneider, and ABB meters to Eziwan.