Use CasesEnergy & Smart Grid
Smart Grid — Substations & Transformers

Remote Management of Your
sous-stations
on industrial 4G LTE

Replace your 2G/3G GPRS modems at your high-voltage substations and distribution transformers. Real-time monitoring, RSRP monitoring, and automatic dual-SIM failover. NIS2 compliance included.

< 60s
SIM Failover
100+
Supervised Positions
99.9%
SLA Availability
Remote Management of Substations — Eziwan
High-Voltage Substation
20 kV/400 V Transformer
ABB High-Voltage Cells
Schneider PM800 Meter
Coil Temperature Sensor
Eziwan
Gateway
Dual SIM LTE
Real-time monitoring
RSRP
-78 dBmExcellent
High-Voltage (HV)
20.1 kVNormal
Courant
142 ANormal
Temperature
68 °CAttention
RSRP-78 dBm
RSRQ-9 dB
SINR14 dB

THE PROBLEM

The end of GPRS has left people in the dark
your substations

The gradual shutdown of 2G and 3G networks since 2023 has cut off monitoring of thousands of electrical substations equipped with GPRS modems. Without reliable monitoring, network operators are forced to conduct systematic and costly on-site inspections.

GPRS Modems Out of Service

The Sierra Wireless, Wavecom, and Cinterion GPRS modems that have been installed in your RTUs for the past 10–15 years no longer work following the shutdown of the 2G/3G networks. Hundreds of units have gone “silent.”

Monitoring Interrupted

Without data feedback, it is impossible to detect power surges, ground faults, transformer overheating, or power outages. Incidents are only discovered when a customer files a complaint.

NIS2 Compliance at Stake

Critical infrastructure operators (distribution system operators, energy providers) must demonstrate continuous monitoring of their assets. Failure to implement remote monitoring exposes them to NIS2/NIS regulatory penalties.

THE EZIWAN SOLUTION

Industrial 4G LTE Gateway
for smart grids and energy

Designed to meet the demands of the energy sector: enhanced electromagnetic immunity, battery power supply, IEC 60870/61850 protocols, and NIS2 cybersecurity.

Replacement of GPRS Modems

Direct migration from your existing GPRS RTUs. The Eziwan gateway connects to the same measurement devices (Modbus, IEC 60870) without the need for rewiring.

Real-Time RSRP Monitoring

Continuous monitoring of LTE signal quality (RSRP, RSRQ, SINR). Alerts in the event of degradation before any loss of supervision.

Multi-station supervision

Centralized dashboard for 100+ substations. Map view, load curves, energy balances, and performance metrics.

Dual SIM Failover

Two multi-carrier SIM cards with automatic switching. Failover time of less than 60 seconds, transparent to your SCADA system.

Predictive Maintenance

Analysis of transformer temperature trends and aging curves. Anticipate failures before they occur.

Secure Remote Access

Built-in OpenVPN/IPSec VPN for remote access to protection relays and substation meters. No open ports, comprehensive audit log.

Integration with Existing SCADA System

REST and MQTT APIs for integration with AVEVA, Wonderware, and SIMATIC WinCC. Compliant with IEC 61968 / IEC 61970 (CIM) for network GIS.

Automatic Energy Balance

Automatic calculation of HV/LV balance sheets, technical losses, and power factor. Automatic export to your asset management tools.

ENERGY USE CASES

Eziwan for all players in the energy sector

Distribution System Operators (DSOs), energy unions, electric utilities

Distribution Network Manager

Problem

Hundreds of HV/LV substations spread across the entire region. The discontinuation of the GPRS network has disrupted remote meter reading for energy meters and remote monitoring of circuit breakers. Maintenance crews must travel to perform tasks that could otherwise be avoided.

Eziwan Solution

Eziwan replaces the GPRS modems at all source stations and HV/LV substations. Modbus data (active and reactive power, voltages, currents, circuit breaker statuses) is transmitted to the platform in real time. The quality of the LTE signal is continuously monitored.

Measured results

−65% reduction in meter-reading visits
High-voltage fault detection in less than 2 minutes
Monthly Automatic Energy Summary Report
Modbus TCPIEC 60870-5-104IEC 61850
Distribution Network Manager

TECHNICAL SPECIFICATIONS

Designed for environments
challenging electrical systems

Electrical Robustness
9–48 V DC Power Supply (Substation Batteries)
EN 61000-4-5: ±2 kV surge immunity
EN 61000-4-4: EFT/burst ±4 kV
EN 61000-4-2: Electrostatic Discharge ±6 kV
Galvanic Isolation of Inputs/Outputs
Connectivity & Protocols
LTE Cat. 4 (150 Mbps download / 50 Mbps upload)
Dual SIM, multi-carrier, failover < 60 seconds
RS-232 / RS-485 (Modbus RTU, IEC 60870-5-101)
Ethernet (Modbus TCP, IEC 60870-5-104)
Built-in OpenVPN/IPSec VPN
Environment & Certifications
Temperature: -40°C to +70°C
IP40 standard, IP65 optional
MTBF > 500,000 hours
CE, RED, RoHS
NIS2-compliant (audit log, encryption)
FAQ

Frequently Asked Questions

GPRS → 4G LTE MIGRATION

Your substations deserve
supervision worthy of the name

Free GPRS migration audit. We analyze your existing infrastructure and propose a phased migration plan that ensures uninterrupted monitoring.

Free Migration AuditView rates
Assisted Migration
Zero service interruptions
NIS2-compatible
Expert Energy Support